GARRETT COMMUNICATIONS MAGNUM TP1 Card Type Ethernet Transceiver NIC Type Ethernet Maximum Onboard Memory Unidentified Boot ROM Not available Network Transfer Rate 10Mbps Topology Linear Bus, Star Wiring Type Shielded twisted pair, Unshielded twisted pair AUI transceiver via DB-15 port Data Bus External [Image] CONNECTIONS Function Label Function Label AUI transceiver via CN1 UTP/STP connector CN2 DB-15 (RJ-45) USER CONFIGURABLE SETTINGS Function Label Position » Automatic correction for reversed SW1 On polarity enabled Automatic correction for reversed SW1 Off polarity disabled » Unshielded twisted pair SW2 Off Shielded twisted pair SW2 On » 10BASE-T enabled SW3 On Starlan 10 (ATT) polarity on the SW3 Off segment » SQE enabled SW4 On SQE disabled SW4 Off DIAGNOSTIC LED(S) LED Color Status Condition LED1 Green On Network connection established LED1 Green Off Network connection is not established LED2 Yellow On Collision has occurred LED2 Yellow Off Collision has not occurred LED3 Green Blinking Data is being received LED3 Green Off Data is not being received LED4 Green On Data is being transmitted LED4 Green Off Data is not being transmitted LED5 Yellow On Polarity error LED5 Yellow Off No polarity error LED6 Yellow On SQE test feature enabled LED6 Yellow Off SQE test feature disabled LED7 Green On Power is on LED7 Green Off Power is off MISCELLANEOUS TECHNICAL NOTES The AUI port should be directly connected to the workstation. If you cannot connect to the workstation, an AUI drop cable (which cannot exceed 3 feet in length) may be used.